
| Cat. No | Model | Burette Drive | Package |
|---|---|---|---|
| T25-162-222 | T50 M | Max. 3ea | w/ Manual Stand |
| T25-162-226 | T50 A | w/ Rondolino Stand |
| Cat. No | Model | Burette Drive |
|---|---|---|
| T25-162-230 | T70 | Max. 3ea |
| Cat. No | Model | Burette Drive |
|---|---|---|
| T25-162-242 | T90 | Max. 7ea |
| Features | Model | |||
|---|---|---|---|---|
| T50 | T70 | T90 | ||
| Analysis Type | Acid / Base, Precipitation (Cl, Br, etc...), Redox, Complexometric and Photometric Titrations, pH Stat, pH and Ion Selective and Conductivity Direct Measurement, Two-phase Titrations Conductivity Titrations | -50 ~ 450¡ÉYes | ||
| Shot Cuts per User | - | 12 | ||
| Hot Plug and Play | Burette Recognition with Titrant and Titer, Recognition of plug & Play Sensor, Burette Drive Rondo Sample Changer, Rondolino Auto. Titration Stand USB Printer, Memory Stick, USB Barcode Reader |
Yes | ||
| Burette Drives | Max. Number to dose and titrate | 1 (internal) | 1 (internal) + 3 External |
1 (internal) + 7 External |
| Max. Nomber to dose only | + 3 External | - | - | |
| Mathod and Series | Learn titration for the automatic optimisation of the titration parameters used in the method |
Yes | ||
| Number of method functions per method | 15 | 60 | 120 | |
| Number of loops per method : Combination of multiple titration in one method |
1 | 3 | 6 | |
| ¡°If....then¡± decisions in method | - | - | Yes | |
| Express Samples ; Can be inserted during the current series | - | Yes | Yes | |
| Series sequences : Combination of individual samples series of different methods |
- | - | 10 | |
| Number of samples per series | 120 | 120 | 120 | |
| Pre-programmed METTLER TOLEDO methods for the most inportant applications |
>30 | |||
| Max. Number of methods | 120 | |||
| Control and Evaluation | End point titration (EP) with dynamic and continuous titrant addition | Yes | ||
| Equivalence point titration (EQP) with dynamic or incremental titrant addition |
Yes | |||
| Five different curve evaluation procedures with EQP Titrations : Standard, Asymmetric, Segmented, Min, Max |
Yes | |||
| Predefined formulas for the most common calculations as well as freely definable calculation formulas |
Yes | |||
| Number of calcuations per methods | 6 | 40 | ||
| Task List | Number of Tasks | - | 10 | 30 |
| Number of Tasks running parallel | - | 7 | 8 | |
| Parallel Titraion | - | - | - | Yes |
| Expandable | - | - | to T90 | - |
| Sensor Boards | Analog or Conductivity (Optional / Standard) | 1 | 2/1 | 3/1 |
| Sensor Inputs | Potentiometric (Optional / Standard) | 2/2 | 4/2 | 6/2 |
| Polarized (Optional / Standard) | 1/1 | 2/1 | 3/1 | |
| Reference (Optional / Standard) | 1/1 | 2/1 | 3/1 | |
| PT1000 (Optional / Standard) | 1/1 | 2/1 | 3/1 | |
| Conductivity (Optional / Standard) | 1/0 | 2/0 | 3/0 | |
| Cat. No | Model | Description |
|---|---|---|
| T25-162-570 | 30094120 | Autosampler InMotion Flex 100 ml |
| T25-162-574 | 30094121 | Base InMotion Flex |
| T25-162-578 | 30094122 | Base InMotion Pro |
| T25-162-582 | 30094123 | Base InMotion Max |